JUTA

HDPE 0.6 MM

JUNIFOL 0.6 MM HDPE High-Density Polyethylene Geomembrane is designed to protect structures from the ingress of moisture, water, liquids, radon, carbon dioxide and methane together with chemicals.

Suitable for use in various demanding geomembrane applications such as SUDS, root barrier, waterproofing and radon protection and permeable paving.

Read More

Product Benefits

  • Designed to perform as a robust waterproofing barrier protection system.
  • Provides resistance to root penetration from invasive species, including (but not limited to): Japanese Knotweed, Bamboo, Mustard seed, Meadow grass, Ivy, Hybrid poplars, Willow, Elm, Maple, Mare’s tail, ground creeping plants, edible plants and aquatic plants.
  • Fully weldable, category 2 attenuation grade liner fully conformant to C753 and BS533-13 and is CE marked for use in EN13967 (A/T) application areas.
Product Description

HDPE 0.6 mm – is a mono layer, high-density polyethylene membrane specifically designed and manufactured to perform as a robust waterproofing barrier protection system, which is suitable for use in various demanding geomembrane applications such as SUDS, root barrier, waterproofing and radon protection and permeable paving.

HDPE 0.6 mm is a fully weldable, category 2 attenuation grade liner fully conformant to C753 and BS7533-13 and is CE marked for use in the following application areas: EN13967 (A/T).

HDPE 0.6 mm provides resistance to root penetration from invasive species, including (but not limited to): Japanese Knotweed, Bamboo, Mustard Seed, meadow Grass, Ivy, Hybrid poplars, Willow, Elm, Maple, Mare’s Tail, ground creeping plants, edible plants and aquatic plants.

HDPE 0.6 MM
ColorBlack
MaterialPolyethylene
High-density polyethylene (HDPE).
Mono-layer, linear high-density polyethylene membrane.
Size2.5 x 50 m x 0.6 mm
Uniclass 2015Pr_25_57_65_60 Plastics sheets
CAWSJ44/115 Geomembrane lining
J44/110 Geomembrane lining
J40/145 Loose laid weldable polyethylene gas retardant damp proofing
J40/140 Loose laid plastics or rubber sheet gas retardant damp proofing
J40/35 Loose laid plastics or rubber gas retardant damp proofing
D20/550 Geotextile sheet
D20/58 Geotextile sheet
Product rangeJunifol Geomembrane
MaterialHigh-density polyethylene (HDPE).
PurposeWaterproof layer.
StandardTo EN 14150, EN 1931, EN 1928, EN 12730-B, EN 12311-2(A), EN 12310-1, EN 12691 (A), EN 12317-2, EN 1269, EN 1847.
Performance characteristics
Tensile strength (minimum) 500 N/50mm.
Tear resistance MD:450 N; CD: 500 N.
Resistant to underground gases Radon.
Physical properties
Thickness (minimum) 0.6 mm.
Width (minimum) 2.5 m / 5.1m
Roll length (minimum) 50 m. / 100 m.
Environmental Information
Country of material origin United Kingdom
CharacteristicsTest MethodHDPE 0.6 MM
ThicknessEN 1849-20.6 mm
WidthEN 1849-22.5 or 5.1 m
LengthEN 1849-250 or 100 m
DensityLength0.939 g/cm3
Resistance to RootsLengthImpenetrable
CharacteristicsTest MethodHDPE 0.6 MM
Permeability to liquidsEN 145101.0 x 10-6 m3/(m2.d)
Water Tightness (60 kPa)EN 1928Pass
CharacteristicsTest MethodHDPE 0.6 MM
Resistance to Static LoadEN 12730-B> 20 kg
Tensile Strength (MD)EN 12311-2 (A)500 N/50mm
Tensile Strength (CMD)EN 12311-2 (A)500 N/50mm
Tear Strength (MD)EN 12310-1450 N
Tear Strength (CMD)EN 12310-1500 N
Resistance to ImpactEN 12691 (A)> 2000 mm
Shear Resistance of JointEN 12317-2Welded: 400 N/50mm GP® TITAN TAPE: 400 N/50mm
CharacteristicsTest MethodHDPE 0.6 MM
Resistance to Elevated TemperatureEN 1296Conforming
Resistance to Liquid ChemicalsEN 1847Conforming
CharacteristicsTest MethodHDPE 0.6 MM
Radon PermeabilityK124/02/952.0 x 10-12 m2/s

HDPE 0.6 mm is a robust weldable geomembrane suitable for attenuation tank encapsulations, porous sub-base installations, containment and cut-off trenches, structural waterproofing. HDPE 0.6 mm is a chemically inert membrane offering designers and specifiers a range of critical properties that meet the needs of today’s demanding geomembrane applications including high water table sites. HDPE 0.6 mm can be fully welded where required.

Installation

HDPE 0.6 mm should be installed on a blinded or smooth surface, free from sharp protrusions (typically maximum permissible particle size in direct contact with the membrane should be < 10mm). Avoid areas of unsupported membrane. Where required, adequate protection should be applied over the membrane to prevent damage after installation. HDPE 0.6 mm exhibits superior welding properties, making it ideal for on-site welding joints.

HDPE 0.6 MM

A selection of standard details for information and education purposes only. Note - it is strongly advised appropriately qualified, and insured personnel undertake gas membrane installs. A gas membrane performs a critical function in the application setting and has an anticipated design service life in excess of 60 years. Do not attempt to install gas membranes from these details alone. Sole rights for use and distribution are owned by JUTA UK LTD.

Store in a clean and dry environment, with tolls stacked no more than 5 units high. HDPE 0.6 mm is classified as non-hazardous. It is chemically inert and is not affected by acids and alkalis that may be present in the subsoils. The material is not recommended for uses where it will be exposed to long periods of outdoor weathering, such as exposure to Ultraviolet light that will embrittle the product. Care should be take to avoid accidental damage when handling the membrane on site.

CE Mark
CE Mark - EN13967:2012 (A/T)
BSI Kitemark
BS7533-13 and ‘Code for Sustainable Homes 2006’ Conformant
Ciria Logo
Conforms to CIRIA C697 and C753 as an Attenuation Membrane
BBA Logo
CE Mark
UKCA Logo
Site Investigation
Site Investigation
Site Investigation Reports Monitoring Results. We review these reports and advise routes for compliance.
System Design
System Design
Full Ground Gas Protection System Design available.
Specification
Specification
Wide library of standard details with site specific details on request.
Installation
Installation
All our installers are certified NVQ Level 2 qualified installation contractors.
Validation
Validation
We ensure your project complies with the relevant building regulations.

Ground Gas Standards 

There are many different standards and guidance documents that detail how to understand the risk of ground contamination, and design solutions to mitigate these risks. The different documents relate to different ground contamination. Below are some of the key documents to be aware of and refer to:

BS 8485:2015+A1:2019 – Codes of practice for the design of protective measures for methane and carbon dioxide ground gases for new buildings.

  • Ground gases typically found near landfill sites, but can occur from other sources
  • Encourages the use of qualified installers
  • Validation to Ciria C735 is a requirement
  • Additional influences on the system should be considered, such as the hydrostatic conditions, and the likelihood of the source contaminant being in direct contact with the protective measures proposed
HDPE 0.6 MM

BRE 211:2015 – Guidance on protective measures for new buildings. (RADON)

  • Naturally occurring ground gas. Larger concentrations in the South-West of UK
  • Minimum recommendation is a membrane of 300 micrometre (1200 gauge) polyethylene sheet or equivalent
  • It must be installed with considerable care and protected once installed
  • Taped laps are required
HDPE 0.6 MM

CIRIA C748:2014 – Guidance on the use of plastic membranes as VOC vapour barriers

CIRIA C682:2009 – VOC Handbook

  • Risk-based approach
  • No quantifiable limits on material performance
  • Testing to ISO 15105-2 and EN 14414/EN 14415
  • 9 main VOC types are tested for
  • Welded laps are required as most tapes are made from bitumen/butyl and are affected by VOCs
HDPE 0.6 MM

CIRIA C735:2014 – Good practice on testing and verification of protection systems to buildings from hazardous gases

  • Good practice on testing and verification of protection systems to buildings from hazardous gases
  • Check design and detailing is in accordance with site requirements
  • Checks the competency of the installer (NVQ LEVEL 2 minimum)
  • Test integrity of the membrane/barrier system
    Visual inspection
    Written report on inspection/testing and sign-off
    BS8102:2009 – Code of practice for protection of below ground structures against water from the ground
HDPE 0.6 MM

JUTA Solutions & Applications

Our gas protection membranes suit a variety of applications and situations, with our TITAN® range offering not only gas protection but also having superior waterproofing and invasive weed control qualities.

BRE 211 NHBC (Amber 1) BS8485:2015 + A1 2019 / NHBC (Amber 2) C748 C748 BS8102:2009 RPS178 C753 BBA Agreement Certificate
Radon Bulk Ground Gasses Cardbon Dioxide and Methane VOC Vapour Permeation Hydrocarbons Immersions TYPE-A Bonded Waterproofing Invasive Weed Control SuDs Impermeable Membrane
GP®1
GP®2
GP®4
GP®5
GP®H
GP®L
GP® TITANFLEX
GP® TITANBOND
GP® TITANTANK
GP® LIQUID BARRIER
GP®H 0.6mm

Get In Touch With The Experts

If you feel first class service, premium products direct from source, and bespoke solutions are right for you then don't hesitate to contact our team today on 01772 754177 or email us at [email protected]

Contact Us