JUTA

JUNIFOL HDPE GRI GM13

JUNIFOL – HDPE (Smooth) is a high-density polyethylene membrane, for use in accordance with harmonised standards.

Read More

Product Benefits

  • BS EN 13361: Characteristics required for use in the construction of reservoirs and dams.
  • BS EN 13362: Characteristics required for use in the construction of canals.
  • BS EN 13492: Characteristics required for use in the construction of liquid waste disposal sites, transfer stations, or secondary containment.
  • BS EN 13493: Characteristics required for use in the construction of solid waste storage and disposal sites.
  • BS EN 15382: Characteristics required for use in the construction of transportation infrastructure.
Product Description

JUNIFOL – HDPE (Smooth) is a high-density polyethylene membrane, for use in accordance with harmonised standards.

  • BS EN 13361: Characteristics required for use in the construction of reservoirs and dams.
  • BS EN 13362: Characteristics required for use in the construction of canals.
  • BS EN 13492: Characteristics required for use in the construction of liquid waste disposal sites, transfer stations, or secondary containment.
  • BS EN 13493: Characteristics required for use in the construction of solid waste storage and disposal sites.
  • BS EN 15382: Characteristics required for use in the construction of transportation infrastructure.
JUNIFOL HDPE GRI GM13
CharacteristicTest Method0.75 mm1.0 mm1.5 mm2.0 mm2.5 mm3.0 mm
MaterialDSC Analysis High Density Polyethylene (HDPE)
Width5.1 m5.1 m or 8.0 m
Length100 m 100 m 100 m 120 m 100 m 85 m
CharacteristicTest Method0.75 mm1.0 mm1.5 mm2.0 mm2.5 mm3.0 mm
Thickness (min. ave.) Lowest individual of 10 values ASTM D 5199 0.75 mm (0.67 mm)1.00 mm (0.9 mm)1.50 mm (1.35 mm)2.00 mm (1.8 mm)2.50 mm (2.25 mm)3.00 mm (2.7 mm)
Density (min) ASTM D 1505 0.942 g/cm3
Tear Resistance (min. ave.) ASTM D 1004 100 N 125 N 187 N 249 N 311 N 374 N
Puncture Resistance (min. ave.) ASTM D 4833 250 N 320 N 480 N 640 N 800 N 960 N
Stress Crack Resistance ASTM D 5397 500 hr.500 hr.500 hr.500 hr.500 hr.500 hr.
Carbon Black Content ASTM D 4218/63702-3 %2-3 %2-3 %2-3 %2-3 %2-3 %
Carbon Black Dispersion ASTM D 5596Min. 9 in Categories 1 or 2 and Max. 1 in Category 3
CharacteristicTest Method0.75 mm1.0 mm1.5 mm2.0 mm2.5 mm3.0 mm
Yield Strength ASTM D 6693 Type IV 12.00 kN/m 15.00 kN/m 22.00 kN/m 29.00 kN/m 37.00 kN/m 44.00 kN/m
Break Strength ASTM D 6693 Type IV 24.00 kN/m 27.00 kN/m 40.00 kN/m 53.00 kN/m 67.00 kN/m 80.00 kN/m
Yield Elongation ASTM D 6693 Type IV 12.00 %12.00 %12.00 %12.00 %12.00 %12.00 %
Break Elongation ASTM D 6693 Type IV 700.00 %700.00 %700.00 %700.00 %700.00 %700.00 %
CharacteristicTest Method0.75 mm1.0 mm1.5 mm2.0 mm2.5 mm3.0 mm
Standard OIT ASTM D 8117 ASTM D 3895 ASTM D 5885150 min.150 min.150 min.150 min.150 min.150 min.
High Pressure OIT ASTM D 8117 ASTM D 3895 ASTM D 5885 500 min.500 min.500 min.500 min.500 min.500 min.
Oven Aging at 85o Standard OIT (min. ave.) % Retained after 90 days ASTM D 5721 ASTM D 8117 ASTM D 3895 ASTM D 5885 80 %80 %80 %80 %80 %80 %
High Pressure (min. ave.) % Retained after 90 daysASTM D 5721 ASTM D 8117 ASTM D 3895 ASTM D 5885-80 %80 %80 %80 %80 %
UV Resistance ASTM D 7238 ASTM D 5885-5050505050
High Pressure OIT - 50 50 50 50 50. (min. ave.) % Retained after 1600 hours ASTM D 7238 ASTM D 5885-5050505050

Installation
JUNIFOL HDPE should be installed in accordance with the product installation guide.

Jointing and Sealing
JUNIFOL HDPE should be jointed and sealed in accordance with the product installation guidelines.

JUNIFOL HDPE GRI GM13

Roll Weights can be in excess of 200kg and hence appropriate care and equipment is required for unloading and handling.

Storage
Rolls of JUNIFOL HDPE should be stored on stable/level ground and stacked not more than five rolls high, with no other material stacked on top. The rolls can be stored outdoors when packaged but should be protected from exposure to UV.

BBA Certificate 20 5728
BBA Certificate 20/5728
CE Mark
UKCA Logo
UKNI Logo
Site Investigation
Site Investigation
Site Investigation Reports Monitoring Results. We review these reports and advise routes for compliance.
System Design
System Design
Full Ground Gas Protection System Design available.
Specification
Specification
Wide library of standard details with site specific details on request.
Installation
Installation
All our installers are certified NVQ Level 2 qualified installation contractors.
Validation
Validation
We ensure your project complies with the relevant building regulations.

Ground Gas Standards 

There are many different standards and guidance documents that detail how to understand the risk of ground contamination, and design solutions to mitigate these risks. The different documents relate to different ground contamination. Below are some of the key documents to be aware of and refer to:

BS 8485:2015+A1:2019 – Codes of practice for the design of protective measures for methane and carbon dioxide ground gases for new buildings.

  • Ground gases typically found near landfill sites, but can occur from other sources
  • Encourages the use of qualified installers
  • Validation to Ciria C735 is a requirement
  • Additional influences on the system should be considered, such as the hydrostatic conditions, and the likelihood of the source contaminant being in direct contact with the protective measures proposed
JUNIFOL HDPE GRI GM13

BRE 211:2015 – Guidance on protective measures for new buildings. (RADON)

  • Naturally occurring ground gas. Larger concentrations in the South-West of UK
  • Minimum recommendation is a membrane of 300 micrometre (1200 gauge) polyethylene sheet or equivalent
  • It must be installed with considerable care and protected once installed
  • Taped laps are required
JUNIFOL HDPE GRI GM13

CIRIA C748:2014 – Guidance on the use of plastic membranes as VOC vapour barriers

CIRIA C682:2009 – VOC Handbook

  • Risk-based approach
  • No quantifiable limits on material performance
  • Testing to ISO 15105-2 and EN 14414/EN 14415\
  • 9 main VOC types are tested for
  • Welded laps are required as most tapes are made from bitumen/butyl and are affected by VOCs
JUNIFOL HDPE GRI GM13

CIRIA C735:2014 – Good practice on testing and verification of protection systems to buildings from hazardous gases

  • Good practice on testing and verification of protection systems to buildings from hazardous gases
  • Check design and detailing is in accordance with site requirements
  • Checks the competency of the installer (NVQ LEVEL 2 minimum)
  • Test integrity of the membrane/barrier system
  • Visual inspection
  • Written report on inspection/testing and sign-off

BS8102:2009 – Code of practice for protection of below ground structures against water from the ground

JUNIFOL HDPE GRI GM13

JUTA Solutions & Applications

Our gas protection membranes suit a variety of applications and situations, with our TITAN® range offering not only gas protection but also having superior waterproofing and invasive weed control qualities.

BRE 211 NHBC (Amber 1) BS8485:2015 + A1 2019 / NHBC (Amber 2) C748 C748 BS8102:2009 RPS178 C753 BBA Agreement Certificate
Radon Bulk Ground Gasses Cardbon Dioxide and Methane VOC Vapour Permeation Hydrocarbons Immersions TYPE-A Bonded Waterproofing Invasive Weed Control SuDs Impermeable Membrane
GP®1
GP®2
GP®4
GP®5
GP®H
GP®L
GP® TITANFLEX
GP® TITANBOND
GP® TITANTANK
GP® LIQUID BARRIER
GP®H 0.6mm

Get In Touch With The Experts

If you feel first class service, premium products direct from source, and bespoke solutions are right for you then don't hesitate to contact our team today on 01772 754177 or email us at [email protected]

Contact Us