JUTA GP®H 0.6mm is a mono layer, high-density polyethylene membrane specifically designed and manufactures to perform as a robust waterproofing barrier protection system, which is suitable for use in various demanding geomembrane applications such as damp/waterproofing and radon protection.

Read More

Product Benefits

  • High quality reinforced polyethylene membranes
  • Provides resistance to ground borne gasses such as methane and carbon dioxide.
  • Fully weldable liner and is CE marked for use in the following application areas: EN13967 (A/T).
  • Provides resistance to root penetration from invasive species.
Product Description

GP® H 0.6 mm – is a mono layer, high-density polyethylene membrane specifically designed and manufactures to perform as a robust waterproofing barrier protection system, which is suitable for use in various demanding geomembrane applications such as damp/waterproofing and radon protection. GP® H 0.6 mm also provides resistance to ground borne gasses such as methane and carbon dioxide. GP® H 0.6 mm is a fully weldable liner and is CE marked for use in the following application areas: EN13967 (A/T).

GP® H 0.6 mm provides resistance to root penetration from invasive species, including (but not limited too): Japanese Knotweed, Bamboo, Mustard Seed, Meadow Grass, Ivy, Hybrid Poplars, Willow, Elm, Maple, Mare’s tail, ground creeping plants, edible plants and aquatic plants.

GP<sup>®</sup>H 0.6 MM
CharacteristicsTest MethodUnit
ThicknessEN 1849-20.6 mm
WidthEN 1849-22.5 or 5.1 m
LengthEN 1849-250 m or 100 m
DensityEN ISO 1183 0.939 g/cm3
Resistance to Roots CEN/TS 14416 Impenetrable
CharacteristicsTest MethodUnit
Permeability to liquids EN 14150 1.0 x 10-6 m3 /(m2.d)
Water Tightness (6o kPa)EN 1928 Pass
CharacteristicsTest MethodUnit
Resistance to Static Load EN 12730-B > 20 kg
Tensile Strength (MD) EN 12311-2 (A) 500 N/50mm
Tensile Strength (CMD) EN 12311-2 (A) 500 N/50mm
Tear Strength (MD) EN 12310-1 450 N
Tear Strength (CMD) EN 12310-1 500 N
Resistance to Impact EN 12691(A) > 2000 mm
Shear Resistance of Joint EN 12317-2 Welded: 400 N/50mm
GP TITAN TAPE: 90 N/50mm
CharacteristicsTest MethodUnit
Resistance to elevated temperature EN1296 Conforming
Resistance to Liquid Chemicals EN1847 Conforming
CharacteristicsTest MethodUnit
Methane Permeability BS EN ISO 15105-1 < 96 ml/m2/day/atm
Carbon Dioxide Permeability BS EN ISO 15105-1 < 96 ml/m2/day/atm
Radon Permeability K124/02/95 2.0 x 10-12 m2/s

GP® H 0.6 mm should be installed on a blinded or smooth surface, free from sharp protrusions (typically maximum permissible particle size in direct contact with the membrane should be <10 mm). Avoid areas of unsupported membrane. Where required, adequate protection should be applied over the membrane to prevent damage after installation. GP® H 0.6 mm exhibits superior welding properties, making it ideal for on-site welding joints.

GP<sup>®</sup>H 0.6 MM

Store in a warm clean and dry environment, with rolls stacked no more than 5 units high. GP® H 0.6 mm is classified as non-hazardous. It is chemically inert and is not affected by acids and alkalis that may be present in the subsoils. The material is not recommended for uses where it will be exposed to long periods of outdoor weathering, such as exposure to Ultraviolet light that will embrittle the product. Care should be taken to avoid accidental damage when handling the membrane on site.

CE Mark
CE Mark - EN13967:2012 (A/T)
UKCA Logo
Site Investigation
Site Investigation
Site Investigation Reports Monitoring Results. We review these reports and advise routes for compliance.
System Design
System Design
Full Ground Gas Protection System Design available.
Specification
Specification
Wide library of standard details with site specific details on request.
Installation
Installation
All our installers are certified NVQ Level 2 qualified installation contractors.
Validation
Validation
We ensure your project complies with the relevant building regulations.

Ground Gas Standards 

There are many different standards and guidance documents that detail how to understand the risk of ground contamination, and design solutions to mitigate these risks. The different documents relate to different ground contamination. Below are some of the key documents to be aware of and refer to:

BS 8485:2015+A1:2019 – Codes of practice for the design of protective measures for methane and carbon dioxide ground gases for new buildings.

  • Ground gases typically found near landfill sites, but can occur from other sources
  • Encourages the use of qualified installers
  • Validation to Ciria C735 is a requirement
  • Additional influences on the system should be considered, such as the hydrostatic conditions, and the likelihood of the source contaminant being in direct contact with the protective measures proposed
GP<sup>®</sup>H 0.6 MM

BRE 211:2015 – Guidance on protective measures for new buildings. (RADON)

  • Naturally occurring ground gas. Larger concentrations in the South-West of UK
  • Minimum recommendation is a membrane of 300 micrometre (1200 gauge) polyethylene sheet or equivalent
  • It must be installed with considerable care and protected once installed
  • Taped laps are required
GP<sup>®</sup>H 0.6 MM

CIRIA C748:2014 – Guidance on the use of plastic membranes as VOC vapour barriers

CIRIA C682:2009 – VOC Handbook

  • Risk-based approach
  • No quantifiable limits on material performance
  • Testing to ISO 15105-2 and EN 14414/EN 14415
  • 9 main VOC types are tested for
  • Welded laps are required as most tapes are made from bitumen/butyl and are affected by VOCs
GP<sup>®</sup>H 0.6 MM

CIRIA C735:2014 – Good practice on testing and verification of protection systems to buildings from hazardous gases

  • Good practice on testing and verification of protection systems to buildings from hazardous gases
  • Check design and detailing is in accordance with site requirements
  • Checks the competency of the installer (NVQ LEVEL 2 minimum)
  • Test integrity of the membrane/barrier system
  • Visual inspection
  • Written report on inspection/testing and sign-off

BS8102:2009 – Code of practice for protection of below ground structures against water from the ground

GP<sup>®</sup>H 0.6 MM

JUTA Solutions & Applications

Our gas protection membranes suit a variety of applications and situations, with our TITAN® range offering not only gas protection but also having superior waterproofing and invasive weed control qualities.

BRE 211 NHBC (Amber 1) BS8485:2015 + A1 2019 / NHBC (Amber 2) C748 C748 BS8102:2009 RPS178 C753 BBA Agreement Certificate
Radon Bulk Ground Gasses Cardbon Dioxide and Methane VOC Vapour Permeation Hydrocarbons Immersions TYPE-A Bonded Waterproofing Invasive Weed Control SuDs Impermeable Membrane
GP®1
GP®2
GP®4
GP®5
GP®H
GP®L
GP® TITANFLEX
GP® TITANBOND
GP® TITANTANK
GP® LIQUID BARRIER
GP®H 0.6mm

Get In Touch With The Experts

If you feel first class service, premium products direct from source, and bespoke solutions are right for you then don't hesitate to contact our team today on 01772 754177 or email us at [email protected]

Contact Us